Due to delays in receiving parts, the assembly and installation time on these custom-built products has been extended to 60 to 90 days.
PLEASE READ THE IMPORTANT NOTICE MESSAGE IN THE "ADDITIONAL INFO" SECTIONS BEFORE PRE-ORDERING
Overview of RTU system: Most rooftop units come with a gas furnace for heat and electric AC for cooling. This packaged unit is ready for heating and cooling and it's located on a commercial roof where it is not convenient to have an indoor furnace and AC. Most rooftop unit has 14 SEER cooling and about 80% efficiency (AFUE), most rooftop package units are an expensive option with a standard efficiency designed for rooftop, but rooftop units last for years to come. Custom-built Power-Heat HP for Roof-Top Units (RTU) HeatLab Heat Pump upgrade system can be designed to be attached to a used or new RTU that works with natural gas furnaces and air conditioning. After installing our Custom-made upgrade Heat Pump system, the RTU unit will significantly increase the efficiency of the overall system by 196% (seasonal).
HeatLab Upgrade System Power-Heat Heat Pump: HeatLab Custom-built Heat pumps for the rooftop unit are a great solution to increase the overall efficiency of the system and save a lot of money on heating costs. HeatLab Custom-built RTU Heat pumps are fit for any type of rooftop unit. HeatLab Custom-built RTU heat pumps are designed to adapt to an existing RTU unit and will increase the overall efficiency of the systems by 196%. This method will become a game-changer in any RTU HVAC/R system in Canada and the US.
Rooftop unit Heat Pump Sizing is critical (efficiency) It's essential to know the sizing of the RTU system before upgrading, which is one of the critical determinants of efficiency and savings. To fit the right heat pump to an existing RTU system, we will evaluate the current system, including the gas furnace, actual efficiency calculations, and air condition cooling output, which will result in a perfect adjustment of the HeatLab RTU Heat Pump and reduce the cost of the total system. A custom-made upgrade to the RTU unit increases the overall efficiency of the unit and eliminates excess costs according to the specific systems already installed. Those parameters will achieve customers with the highest possible return on investment (ROI).
HVAC system optimization is the best opportunity In Canada, any RTU is working on gas furnace heating, for about 8 months and air conditioning for summertime. Each HeatLab Custom-built upgrade RTU Heat Pump unit is designed for a specific existing RTU system. Each project has a different upgrade design and a custom RTU heat pump can be optimized to suit this particular purpose. HeatLab custom-made RTU heat pumps are customized, optimized, and calibrated specifically for each existing rooftop unit model. The rooftop unit upgrade is essential for reducing heating costs and harmful emissions More than 90% of the rooftop units are mid-efficient RTU. Mid-efficient RTU has poor heating efficiency (about 80%) which causes high heating costs. HeatLab Custom-made upgrade rooftop unit heat pump will increase the overall efficiency, and save on energy costs for the client. Knowing the exact needs of each existing rooftop unit system can help customize the upgrading system, which means that component selection can reduce overall costs and rapid ROI.
Why HeatLab custom-made upgrades heat pumps - One-Of-a-Kind system: Upgrading an existing rooftop unit will save a lot of money on heating costs. HeatLab custom-made upgrade RTU heat pumps are unique. We can design the upgrade system, especially for the customer's existing rooftop unit, from 2 tons (24K BTUs cooling) (50K Btu's heating furnace) and above, with 80% efficiency. Upgrading a rooftop unit system will increase the efficiency significantly, from 80% (COP of 0.81) to (COP of 1.96). HeatLab upgrading system is affordable, with up to 2 years ROI for the customer. Attention to detail means an affordable system and less energy cost HeatLab's main business model is to improve the overall efficiency of existing rooftop units without replacing a working system only because it is old and/or less efficient. An old system can continue working for many years without the need to replace it. Our Custom-built upgrades RTU heat pumps to make them affordable and reliable. We evaluate each RTU model with the customer and calculate what will be the total rooftop unit upgrade cost.
QUICK FACTS All in one package Increase the efficiency significantly, from 81% (COP of 0.81) to 196% (COP of 1.96) Custom-made design for each rooftop unit model Ready to install - after pre-design significantly saves on heating bills immediately after installation and adjustment Affordable price with ROI of up to two years Durability and Reliability HeatLab rooftop upgrading system is durable with high-end parts, very reliable and will serve the customer for years to come.
Installation and Maintenance: The HeatLab RTU heat pump upgrade packaged unit uses out-of-the-box parts, the RTU upgrade kit is purchased separately. For ease of installation, the RTU HP Kit is Custom-made and designed specifically for each RTU model from our facility with all required controllers and the necessary parts which will decrease materials and installation costs.